NC-100 MINI CIRCUIT BREAKERGENERAL1.1Application:For protecting equipment against overload and short circuit1.2General rules for choosing MCBTechnicala data of the network at the point considered:The earthing systems(TNS,INC),Shrot-circuit current at the circuit-breaker installatino point,which must always be less than the break

Featured Products

Free Sample! Nc MCB Electrical 3 Phase Circuit Breaker

Free Sample! Nc MCB Electrical 3 Phase Circuit Breaker
Free Sample! Nc MCB Electrical 3 Phase Circuit Breaker

NC-100 MINI CIRCUIT BREAKER

GENERAL

1.1Application:

For protecting equipment against overload and short circuit

1.2General rules for choosing MCB

Technicala data of the network at the point considered:

The earthing systems(TNS,INC),Shrot-circuit current at the circuit-breaker installatino point,which must always be less than the breaking capacity of this device,Networl normal voltage.

 Standard IEC/EN 60947-2
Electrical featuresRated current InA63,80,100,125
Poles 1P,2P,3P,4P
Rated voltage UeV230/400
Insulation voltage UiV500
Rated frequencyHz50/60
Rated breaking capacityKa6~10
Rated impulse withstand voltage(1.2/50)UimpV6000
Dielectric test voltage at ind.Freq.for 1 minKv2.5
Pollution degree 3
Thermo-magnetic release characteristic 8-12In
Mechanical
features
Electrical life 1500(In=63A,80A,100A)
1000(In=125A)
Mechanical life 8000(In=63A,80A,100A)
7000(In=125A)
Contact position indicator Yes
Pollution degree IP20
Standard IEC/EN 60947-2
Reference temperature for
setting of thermal element
ºC30
Ambient temperatureºC

-5...+40

(Special application please refer to P29 

for temperature compensation correction)

Combination
with
sccssorles
(with daily average≤35ºC) 
Storage temperation Terminal connection typeºC-25..+70
 Cable/pin-type busbar
Terminal size top/bottom for cablemm250
AWG18-1/0
Terminal size top/bottom for busbarmm250
AWG18-1/0
Tightening torqueN*m3.5
In-Ibs.3.1
Mounting 

On DN rail EN 60715(35mm)

by meas of fast clip device 

Connection
Auxilary contact
 From top 
Auxilary contact Yes
Rated current
 In (A)
Temperature compensation coefficient under various operational temperature
 -10ºC0ºC10ºC20ºC30ºC40ºC50ºC55ºC60ºC
631.281.211.141.071.000.840.870.850.82
801.221.161.111.051.000.950.910.880.86
1001.221.181.111.051.000.950.910.880.88
1251.221.161.111.051.000.950.910.880.86
Free Sample! Nc MCB Electrical 3 Phase Circuit Breaker
Free Sample! Nc MCB Electrical 3 Phase Circuit Breaker
Free Sample! Nc MCB Electrical 3 Phase Circuit Breaker
Free Sample! Nc MCB Electrical 3 Phase Circuit Breaker
Free Sample! Nc MCB Electrical 3 Phase Circuit Breaker
Free Sample! Nc MCB Electrical 3 Phase Circuit Breaker
Free Sample! Nc MCB Electrical 3 Phase Circuit Breaker
Free Sample! Nc MCB Electrical 3 Phase Circuit Breaker

 

Contact us

Please feel free to give your inquiry in the form below We will reply you in 24 hours