Good Quality Ds941 2pole AC RCCB Circuit Breaker

10 KA according  IEC 60947-2 and IEC 60947-4Miniature Circuit Breakers (MCB) which can be used in low voltage electrical installations to protect conductors, switchgear, and electrical equipment in general against overload and short-circuit.1.Specifications   Electrical FeatureStandard IEC61008-1Typ

Featured Products

10 KA according  IEC 60947-2 and IEC 60947-4
Miniature Circuit Breakers (MCB) which can be used in low voltage electrical installations to protect conductors, switchgear, and electrical equipment in general against overload and short-circuit.
1.Specifications   
Electrical 
Feature
Standard IEC61008-1
Type(wave form of the earth leakage sensed) AC,A
Rated current InA25,40,63
PolesP2,4
Rated voltage UeV230/400
Rated sensitivity I nA0.03,0.1,0.3  0.5
Insulation voltage UiV500
Rated residual making andA500(In=25A/40A)
breaking capacity I m 630(In=63A)
Short-circuit current I cA6000/10000
SCPD fuseA10000
Break time under I ns<0.1
Rated frequencyHz50/60
Rated impulse withstand voltage(1.2/50)UimpV6000
Dielectric test voltage at ind Freq for 1 minkV2.5
Pollution degree 2
MechanicaI
features
Electrical lifet4000
MechanicaI Iifet20000
Fault current indicator Yes
Protection degree IP20
Ambient temperatureC-5~+40
(with daily average 35 )  

Product Description
Electrical Features
Rated current In: 1, 2, 3, 4, 6, 10, 16, 20, 25, 32, 40, 50, 63A
Poles: 1P, 1P+N, 2P, 3P, 3P+N, 4P
Rated voltage Ue: 240/415V
Insulation voltage Ui: 500V
Rated frequency: 50/60Hz
Rated breaking capacity: 6000/10000A
Energy limiting class: 3
Rated impulse withstand voltage(1.2/50) Uimp: 4000V
Dielectric test voltage at ind. Freq. For 1 min: 2kV
Pollution degree: 2
Thermo-magnetic release characteristic: B, C, D
Mechanical Features
Electrical life: 8, 000
Mechanical life: 20, 000
Contact position indicator: Yes
Protection degree: IP20
Reference temperature for setting of thermal element: 30º C
Ambient temperature (with daily average≤ 35º C): -5º C...+40º C
Storage temperation: -25º C...+70º C
Installation
Terminal connection type: Cable/U-type busbar/Pin-type busbar
Terminal size top/bottom for cable: 25mm2 18-3AWG
Terminal size top/bottom for busbar: 25mm2 18-3AWG
Tightening torque 2.0 N*m 22 In-Ibs.
Mounting: On DIN rail EN 60715 (35mm) by means of fast clip device
Connection: From top and bottom
Combination with accessories
Auxiliary contact: Yes
Shunt release: Yes
Under voltage release: Yes
Alarm contact: Yes
 

Contact us

Please feel free to give your inquiry in the form below We will reply you in 24 hours