Gym1e-125 40A 3 Phase Moulded Case Circuit Breaker MCCB with Kema Ce CB Certification

Koyann GYM1E-125 3p/4p Electronic Molded Case Circuit Breaker MCCB with IEC60947-2Product model and meaningThe main features1. Optional coordination: GYM1E electronic plastic case circuit breaker has a three-stage protection function. The circuit breaker of category B and other short-circuit protection devices connected in the s

Featured Products


Koyann GYM1E-125 3p/4p Electronic Molded Case Circuit Breaker MCCB with IEC60947-2

Product model and meaning
Gym1e-125 40A 3 Phase Moulded Case Circuit Breaker MCCB with Kema Ce CB Certification
The main features
1. Optional coordination: GYM1E electronic plastic case circuit breaker has a three-stage protection function. The circuit breaker of category B and other short-circuit protection devices connected in the same circuit have a selective coordination under short-circuit condition;
2. Three-stage protection operation current and operation time can be selected: the user can set and adjust the trip according to the requirements of load current;
3. Self-power supply: the electronic trip is powered by the circuit breaker itself. The current signal and the working power of the trip come from the current transformer installed in the circuit breaker;
4. With "warning" indication: When the actual operating current flowing through the circuit breaker reaches or exceeds the Iro, the "pre-alarm" LIGHT emitting diode on the cover of the circuit breaker will indicate yellow;
5. Overload indicator;When the load current exceeds the overload long delay action current, the light emitting diode on the surface cover of the circuit breaker indicates red.
6. Large-current instantaneous trip function: when the circuit breaker is closed or in operation, in case of short-circuit with large-current (≥20lnm), the circuit breaker shall be directly trip by electromagnetic trip mechanism;
7. Interchangeability in installation: the external dimensions are the same as those of conventional molded case circuit breakers.

There are three and four poles according to the number of product poles.The type of neutral electrode (N pole) of quadrupole product is: the current and time parameters of n-pole overcurrent protection automatically track the setting value of phase line by 100%, and the N pole combines with other three poles (the N pole first combines and then divides);
Rated current of shell frame: GYM1E-125;
                                              GYM1E - 250;
                                              GYM1E - 400;
                                              GYM1E - 630;
                                              GYM1E - 800;
                                              GYM1E - 1250;
The wiring modes can be divided into five types: front wiring, back wiring, front wiring, back wiring, and drawn wiring.
There are two kinds of accessories according to whether the circuit breaker is equipped with accessories or not.
Accessories are divided into internal accessories and external accessories: the internal accessories include shunt trip, undervoltage trip, auxiliary contact and alarm contact.
The external accessories are rotary handle operation mechanism and electric operation mechanism

Technical Parameter
ModelGYM1E
-100(125)
GYM1E
-250
GYM1E -400GYM1E -630GYM1E -800GYM1E-1250
Rated Frame Current Inm(A)1252504006308001250
Rated current In(A)16,20
25,32
32,35
40,45
50,55
60,63
63,65
70,75
80,85
90,95
125
100,125
140,160
180,200
250
200,225
250,280
315,350
400
400,420
440,460
480,500
530,560
600,630
315,350
400,450
500,560
630,700
750,800
400,450
500,550
600,650
700,750
800
630,680
720,780
820,900
950,1000
400,500
630,700
800,1000
1100,1250
Rated working voltage Ue(V)400400
Rated Insulation Voltage Ui(V)800800
Rated Impulse Voltage Uimp(V)80008000
No. of Pole3,43,43,43,43,43
Grade of Breaking CapacityLMHLMHLMHLMHLMH 
Rated limit short circuit segment capability lcu(KA)AC400V35508535508565851006585100658510080
Rated short circuit operation capacitylcs(KA)AC400V22355022355042556542556542556550
Rated operating short circuit withstand current lcw(KA)/1S 581015
Use typeAABBBB
Electrical life80008000750075007500500
Mechanical life20000200001000010000100002500
Overall dimensions(mm)W92 122107 142150 198210 280210 280210
L150165257280280340
H9290106.5115.5115.5138.5

Release mode and internal accessory code
Gym1e-125 40A 3 Phase Moulded Case Circuit Breaker MCCB with Kema Ce CB Certification
Note: The way of triplet trip and the code number of internal accessories the first number 3 represents the electronic trip with three-section protection;The last two digits represent the internal attachment code, or 00 if there is no attachment.

Gym1e-125 40A 3 Phase Moulded Case Circuit Breaker MCCB with Kema Ce CB CertificationGym1e-125 40A 3 Phase Moulded Case Circuit Breaker MCCB with Kema Ce CB Certification
v
 
 

Contact us