Miniature Circuit Breakers Cjm13, MCB, Circuit Breaker 13mm Safe Protector

CJM13Mini Circuit BreakerStandard: IEC60898Construction and Feature  Protection against both overload and short circuit  High short-circuit capacity  Easy mounting onto 35mm DIN railTechnical Data Pole No.:  1P,2P,3P,4P,1P+N,3P+NRated voltage: AC 230/400VRated current (A): 1,2,3,4,6,10,16,

Featured Products

CJM13Mini Circuit Breaker
Standard: IEC60898

Construction and Feature 
 Protection against both overload and short circuit 
 High short-circuit capacity 
 Easy mounting onto 35mm DIN rail
Technical Data
 
Pole No.:  1P,2P,3P,4P,1P+N,3P+N
Rated voltage: AC 230/400V
Rated current (A): 1,2,3,4,6,10,16,20,25,32
Tripping curve: B  C  D
Rated short-circuit capacity (Icn):  6kA
Rated frequency: 50/60Hz
Energy limiting class: 3
Rated impulse withstand voltage: 6.2kV
Electro-mechanical endurance: 4000
onnection terminal: Pillar terminal with clamp
Connection capacity: Rigid conductor up to 25mm2
Fastening torque: 2.0Nm
Installation:
On symmetrical DIN rail 35mm
Panel mounting
Terminal Connection Height: 21mm
Accessories 
F2 Auxiliary contact
S2 Shunt tripper
U2+O2 over-voltage & under-voltage tripper
 
1.The catalogue conveys the latest product information for detailed reference by purchasing/designing staff dedicated to electrical industrycommercial and household installation. 
2.Other than separate stipulation, the normal operation conditions of our products (excluding components) are referred as below:

...Altitude above sea level less than 2000m; 
...Ambient temperature -5~+40, average temperature not exceeding +35 within 24 hours; 
...Relative Humidity not exceeding 50% at maximum temperature +40 higher relative humidity allowed at lower temperature. For          example, relative humidity 90% allowed at +20; 
...Pollution class: II (means generally only non-electricity conducting pollution is considered, and also considers temporary electricity    conducting pollution occasionally caused by condensed dew);
...Perpendicular installation with allowed tolerance  5. 

3.Terminal electric devices shall be mounted on Din rail of TH35-7.5D type.

Miniature Circuit Breakers Cjm13, MCB, Circuit Breaker 13mm Safe ProtectorMiniature Circuit Breakers Cjm13, MCB, Circuit Breaker 13mm Safe ProtectorMiniature Circuit Breakers Cjm13, MCB, Circuit Breaker 13mm Safe ProtectorMiniature Circuit Breakers Cjm13, MCB, Circuit Breaker 13mm Safe ProtectorMiniature Circuit Breakers Cjm13, MCB, Circuit Breaker 13mm Safe ProtectorMiniature Circuit Breakers Cjm13, MCB, Circuit Breaker 13mm Safe Protector

 
 

Contact us

Please feel free to give your inquiry in the form below We will reply you in 24 hours