1p, 2p, 3p, 4p DC Non Polarized DC Circuit Breaker with TUV Certificate (1A-63A)

The JB is a DC circuit breaker dedicated to multi string photovoltaic installations.Storage -40 to 85 degree- This circuit breaker is designed to protect the cables located between each string of photovoltaic modules and the photovoltaic inverter against overloads and short circuits (see application diagram).- Combined with a sw

Featured Products

The JB is a DC circuit breaker dedicated to multi string photovoltaic installations.

Storage -40 to 85 degree

- This circuit breaker is designed to protect the cables located between each string of photovoltaic modules and the photovoltaic inverter against overloads and short circuits (see application diagram).
- Combined with a switch , the JB will be installed in a string PV protection enclosure at the end of each string of photovoltaic modules.
- It can be locked (by a padlocking device) in OFF position as a safety measure for removal of the PV inverter.
- Since a fault current can flow in the reverse direction to the operating current, the JB can detect and protect against any bidirectional current.
- To ensure the safety of the installation, it is necessary, depending on the various types of application, to combine the JB with:
a residual current device at the AC end
a fault passage detector (insulation monitoring device) at the DC end
an earth protection circuit breaker at the DC end
- In all cases, fast action on site will be required to clear the fault (protection not ensured in the event of a double fault).
- JB is not polarity sensitive: (+) and (-) wires can inversed without any risk.
- The JB is: delivered with three inter-pole barrier to provide increased isolation distance between two adjacent connectors.

Main characteristics

Operating Voltage (Ue)1P=250 V DC, 2P=500 V DC
3P=750 V DC, 4P=1000 V DC
Rated insulation voltage (Ui)1,000 VDC
Breaking capacity (Icu)10 kA
Impulse voltage (Uimp)4 kA
Electrical connectionBy the bottom for In and Out
Number of poles1P, 2P, 3P, 4P
StandardsIEC 60947-2
EN 60947-2

 

Rated service breaking capacity (Ics)100% of the Icu
Endurance (O-C)Electrical1,500 cycles (where L/R=2 ms)
Mechanical20, 000 cycles
  
Mechanical20, 000 cycles
Degree of pollution2
CategoryA (no delay in accordance with IEC / EN 60947-2 standards)
Degree of protection
(IEC 60529)
IP40
TropicalisationRelative humidity: 95% at 55 degree in accordance with
IEC 60068-2 and GB 14048.2 standards
TemperatureOperating-25 to 70  degree
Storage-40 to 85 degree


1p, 2p, 3p, 4p DC Non Polarized DC Circuit Breaker with TUV Certificate (1A - 63A)


1p, 2p, 3p, 4p DC Non Polarized DC Circuit Breaker with TUV Certificate (1A - 63A)